Track Parameter Calculator

This calculator uses rule of thumb data which will be more than accurate enough in most cases. It should however, be used with intelligence.

Naturally, I cannot be held liable for any damage or loss as a consequence of its misuse.

Parameters marked with a * are required. Others are optional.

 

Track width
thou mm
*Enter the track width in your preferred units
Copper thickness
oz/sq. ft
*Enter the copper thickness in your preferred units
thou µm
Track length
inch mm
Used to calculate resistance, voltage drop and power
Operating current
A
DC or RMS operating current - used to calculate voltage drop and temperature rise (<30A)
Internal track?
Select if the track is on an internal layer - used to calculate temperature rise
Frequency
MHz
Signal frequency - leave at 0 for DC
Reference plane?
Select if there is a plane under the track - used to calculate skin depth proximity effect

 
 
Cross sectional area
sq. thou sq. mm
Cross sectional area of the track
Temperature rise
°C
Calculated at selected frequency - make sure that you have selected internal or external track above
Skin depth
thou µm
Skin depth at selected frequency
Skin ratio
%
Percentage of cross sectional area used at selected frequency
Resistance
ohms
Resistance of track at selected frequency
Voltage drop
mV
Voltage drop along track at selected frequency
Power dissipated
W
Power dissipated in track at selected frequency


legal Copyright © 2019 Brian Molyneux